Items 1-5 of 5
Sort

Power-Line Router PL3150-FT3150-RTR

LonWorks® Router Line Power

The Power Line Router gives users optimum performance and flexibility in commercial, industrial and residential LonWorks applications that have the ability to use standard Power Line as part of the network topology. Designed using the Smart Transciever Neuron processor, it is used to route LonTalk/LonWorks packets between a twisted pair (TP-FT-10) and power line (PL-20) network channel. The router is a commercial-grade, two channel ANSI/EIA709-1 certified device and provides 2-Amp power line signaling through a 3-Phase transformer isolated coupling circuitry. Once installed, the router is configured using Echelon's LonMaker or other LonWorks network management tool, and can be installed as a repeater or configured as a router or learning router.

  • $675.00

SunSpec PVMet-100 Weather Station w/POA

Made in the USA - The PVMet-100 is the entry level SunSpec/ModBus weather station, preassembled and simple to install.

  • $1,552.50

SunSpec PVMet150; Weather Station w/CMP3

Made in the USA - The PVMet-150 is a SunSpec/ModBus weather station with an integrated CMP3, preassembled and simple to install.

  • $3,300.50

WattNode BACnet-VAC P to N 120-140, P to

WNC-3D-240-BN

WattNode BACnet-VAC P to N 120-140, P to P 208-240

VAC Phase to Neutral 120-140

VAC Phase to Phase 208-240

No Neutral Required

Electrical Service Types

  • 1 Phase 2 Wire 208V (No neutral)
  • 1 Phase 2 Wire 240V (No neutral)
  • 1 Phase 3 Wire 120V/240V
  • 3 Phase 3 Wire 208V (No neutral)
  • 3 Phase 4 Wire 120V/208V

WattNode BACnet

The WattNode BACnet is a kilowatt hour kWh energy and power meter that communicates on a EIA RS-485 network, measures 1, 2, or 3 phases with voltages from 120 to 600 volts Vac and currents from 5 to 6,000 amps in delta (phase to phase) and wye (phase to neutral) configurations.

Diagnostic LEDs

Our diagnostic LEDs provide a per-phase indication of power (green flashing) and negative power (red flashing) to help troubleshoot connection problems, like swapped CTs, or excessive line voltage. The WattNode BACnet meter also has a red/yellow/green communication LED to indicate traffic, configuration problems, bus contention and other conditions. See the manual for full descriptions.

Measurements

  • True RMS Power - Watts (Phase A, B, C, and sum of all phases)
  • Reactive Power - VARs (Phase A, B, C, and sum of all phases)
  • Power Factor (Phase A, B, C, and average of all phases)
  • True RMS Energy - Watthours Wh kWh (Phase A, B, C, and sum of all phases)
  • Reactive Energy - VAR-hours (Phase A, B, C)
  • AC Line Frequency
  • RMS Voltage (Average and Phase A, B, C phase-to-phase and phase-to-neutral )
  • RMS Current (Phase A, B, C)
  • Demand
  • Peak Demand

Features

  • Small form factor for easy installation inside most electrical panels, see a sample installation diagram
  • Pluggable screw terminals for easy wiring
  • 0.5% accuracy nominal (see manual for details)
  • True RMS power even with leading or lagging power factor and chopped or distorted waveforms
  • Measure variable speed drive pumps and motors
  • Uses safe CT's (current transformers), producing 0.333 Vac at rated current.
  • Split core CTs for quick installation
  • Solid core CTs are less expensive and prevent tampering
  • Bus bar CTs for high current applications (standard and custom sizes)
  • UL, cUL Listed, CE Mark - Designed and tested for safety and use throughout North America and the European Union.
  • Assembled in USA, qualified under the Buy American provision in the American Recovery and Reinvestment Act of 2009 (ARRA).
  • Five year warranty

Data SheetUser Manual

  • $392.00

WattNode BACnet-VAC P to N 230, P to P 4

WNC-3Y-400-BN

WattNode BACnet-VAC P to N 230, P to P 400

VAC Phase to Neutral 230

VAC Phase to Phase 400

Neutral Required

Electrical Service Types

  • 1 Phase 2 Wire 230V with neutral
  • 3 Phase 4 Wire 230V/400V

WattNode BACnet

The WattNode BACnet is a kilowatt hour kWh energy and power meter that communicates on a EIA RS-485 network, measures 1, 2, or 3 phases with voltages from 120 to 600 volts Vac and currents from 5 to 6,000 amps in delta (phase to phase) and wye (phase to neutral) configurations.

Diagnostic LEDs

Our diagnostic LEDs provide a per-phase indication of power (green flashing) and negative power (red flashing) to help troubleshoot connection problems, like swapped CTs, or excessive line voltage. The WattNode BACnet meter also has a red/yellow/green communication LED to indicate traffic, configuration problems, bus contention and other conditions. See the manual for full descriptions.

Measurements

  • True RMS Power - Watts (Phase A, B, C, and sum of all phases)
  • Reactive Power - VARs (Phase A, B, C, and sum of all phases)
  • Power Factor (Phase A, B, C, and average of all phases)
  • True RMS Energy - Watthours Wh kWh (Phase A, B, C, and sum of all phases)
  • Reactive Energy - VAR-hours (Phase A, B, C)
  • AC Line Frequency
  • RMS Voltage (Average and Phase A, B, C phase-to-phase and phase-to-neutral )
  • RMS Current (Phase A, B, C)
  • Demand
  • Peak Demand

Features

  • Small form factor for easy installation inside most electrical panels, see a sample installation diagram
  • Pluggable screw terminals for easy wiring
  • 0.5% accuracy nominal (see manual for details)
  • True RMS power even with leading or lagging power factor and chopped or distorted waveforms
  • Measure variable speed drive pumps and motors
  • Uses safe CT's (current transformers), producing 0.333 Vac at rated current.
  • Split core CTs for quick installation
  • Solid core CTs are less expensive and prevent tampering
  • Bus bar CTs for high current applications (standard and custom sizes)
  • UL, cUL Listed, CE Mark - Designed and tested for safety and use throughout North America and the European Union.
  • Assembled in USA, qualified under the Buy American provision in the American Recovery and Reinvestment Act of 2009 (ARRA).
  • Five year warranty

Data SheetUser Manual

  • $392.00